The following prices are limited to services in Japan. For the prices of services outside Japan, consult your local Cosmo representatives.
Product Name/ Specifications |
Price(JPY) | Range / Inspection | Item to be Inspected |
---|---|---|---|
Standard type (LS/LU Series) |
34,000 | Standard pressure range | < Common Inspection Items > – DPS accuracy check – DPS leak check (Only for models of the high pressure range) – PS accuracy check / Analog pressure gauge accuracy check – No-leak Check – Test pressure variation check – Flow check – Charge Hold check – I/O check – Limit alarm check – Insulation resistance check – Overall diagnosis |
39,000 | High pressure range | ||
89,000 | Extremely high pressure range | ||
+10,000 | Multi-range inspection | ||
Micro volume type (LUA/SS Series) |
44,000 | Basic Inspection | |
Micro volume detection type (LZ/ZL Series) |
– Common Inspection Items – Repeatability check |
||
Volume detection type (LSW / LUW / WL Series) |
– Common Inspection Items – Volume check – Tank repeatability check |
||
Air volume tester (AV Series) |
64,000 | Basic Inspection | – Common Inspection Items |
Package leak tester (PL Series) |
28,000 | Basic Inspection | – Common Inspection Items |
Gauge pressure decay type (LSG / GX1 Series) |
32,000 | Standard range | – Pressure accuracy check – No-leak Check – I/O check – Insulation resistance check – Overall diagnosis |
37,000 | High pressure range |
Product Name/ Specifications |
Price(JPY) | Range/Inspection | Item to be Inspected |
---|---|---|---|
Air Flow Tester (AF Series) |
54,000 | Basic Inspection | – Flow accuracy check – PS accuracy check / Analog pressure gauge accuracy check – No-leak Check – I/O check – Limit alarm check – Insulation resistance check – Overall diagnosis |
+7,000 | Atmospheric pressure sensor accuracy check | ||
+22,000 | Two-range inspection | ||
Air flow meter (DF Series) |
61,000 | Standard model: Up to 2 ranges | – Flow accuracy check – Pressure accuracy check (Only for models of the automatic line pressure compensation) – I/O check – Limit alarm check – Insulation resistance check – Overall diagnosis |
83,000 | Standard model: Up to 3 ranges | ||
105,000 | Standard model: Up to 4 ranges | ||
127,000 | Standard model: Up to 5 ranges | ||
149,000 | Standard model: Up to 6 ranges | ||
171,000 | Standard model: Up to 7 ranges | ||
193,000 | Standard model: Up to 8 ranges | ||
68,000 | Automatic line pressure compensation model: Up to 2 ranges | ||
90,000 | Automatic line pressure compensation model: Up to 3 ranges | ||
112,000 | Automatic line pressure compensation model: Up to 4 ranges | ||
134,000 | Automatic line pressure compensation model: Up to 5 ranges | ||
156,000 | Automatic line pressure compensation model: Up to 6 ranges | ||
178,000 | Automatic line pressure compensation model: Up to 7 ranges | ||
200,000 | Automatic line pressure compensation model: Up to 8 ranges | ||
37,000 | Indicator Unit check (Standard type) | ||
44,000 | Indicator Unit check (Automatic line pressure compensation type) | ||
+7,000 | Atmospheric pressure sensor accuracy check | ||
+7,000 | Line pressure inspection (Per range) | ||
+7,000 | Data entry of inspection result of other manufacturers’ laminar flow tube | ||
Deviation flow meter (FD Series) |
34,000 | Basic Inspection | – DPS accuracy check – PS accuracy check / Analog pressure gauge accuracy check – No-leak Check – I/O check – Limit alarm check – Insulation resistance check – Overall diagnosis |
Flow gauge – Mass flow gauge * The same prices apply to the inspection of a Mass Flow Sensor unit. – Laminar flow gauge – Venturi flow gauge |
50,000 | Atmospheric pressure inspection | – Flow accuracy check – I/O check – Limit alarm check – Insulation resistance check – Overall diagnosis |
55,000 | Line pressure inspection | ||
100,000 | MF-140 unit bidirectional (positive, negative) flow inspection | ||
Dynamic flow meter (DF-720) |
57,000 | Atmospheric pressure inspection | |
62,000 | Line pressure inspection | ||
22,000 | Indicator Unit check | ||
+22,000 | Two-range inspection | ||
Digital conditioner (DC-720 flow meter model) |
37,000 | Atmospheric pressure inspection | |
42,000 | Line pressure inspection | ||
22,000 | Indicator Unit check | ||
Leak Master Checker (LMC Series) |
46,000 | One-range inspection | – Flow accuracy check – Pressure accuracy check – No-leak Check – Insulation resistance check – Overall diagnosis |
90,000 | Two-range inspection |
Product Name/ Specifications |
Price(JPY) | Range/Inspection | Item to be Inspected |
---|---|---|---|
Leak Master (LM Series) |
16,500 | Standard range | – Leak measurement – External leak check |
26,500 | High pressure range (1 M to less than 7 M) |
||
31,500 | High pressure range (7 M or higher) |
||
19,500 | J1 model | ||
+6,500 | Additional range(1 point) | ||
Flow Master (FM Series) |
21,500 | Basic Inspection | |
+6,500 | Additional range(1 point) | ||
Laminar Flow Tube (LF Series) |
37,000 | F.S. range: 10 mL to 500 L/min | – Flow accuracy check – No-leak Check |
Rotameter | 35,000 | F.S. range: 10 mL to 500 L/min | – Flow accuracy check |
Product Name/ Specifications |
Price (JPY) | Range/Inspection | Item to be Inspected |
---|---|---|---|
DP Gauge (DP Series) * The same prices apply to the inspection of a pressure transducer unit. |
27,500 | Standard range | – Accuracy check – I/O check – Insulation resistance check – Overall diagnosis |
36,500 | Absolute pressure range | ||
38,000 | Pressure/Vacuum range | ||
36,500 | Highly responsive differential pressure sensor PT-162A unit inspection |
||
Digital manometer (DM Series) |
30,500 | Standard range | |
41,500 | Absolute pressure range | ||
43,000 | Pressure/Vacuum range | ||
+12,500 | Two-range inspection | ||
Digital conditioner / Multi controller (DC-720/MC-720 pressure gauge model) |
32,000 | Standard range | |
41,000 | Absolute pressure range | ||
42,500 | Pressure/Vacuum range | ||
22,000 | Indicator Unit check | ||
Pressure calibrator (PC-3000) |
37,000 | Basic Inspection | – Accuracy check – Variable volume tank check – Insulation resistance check – Overall diagnosis |
Product Name/ Specifications |
Price(JPY) | Range/Inspection | Item to be Inspected |
---|---|---|---|
Setting manometer (SM Series) |
47,000 | Standard range | – Accuracy check – I/O check – Insulation resistance check – Overall diagnosis – Control check (Adjustment) – Aging test |
57,000 | Absolute pressure range | ||
59,000 | Pressure/Vacuum range | ||
Pressure controller (PC Series) |
47,000 | Standard range | |
57,000 | Absolute pressure range | ||
59,000 | Pressure/Vacuum range | ||
Pressure/Flow Controller (PR Series) |
47,000 | Standard range | |
59,000 | Pressure/Vacuum range |
Product Name/ Specifications |
Price(JPY) | Range/Inspection | Item to be Inspected |
---|---|---|---|
Movelet (MV Series) |
55,000 | Basic Inspection | – Frequency check – I/O check – Performance check – Insulation resistance check – Overall diagnosis |
Product Name/ Specifications |
Price(JPY) | Range/Inspection | Item to be Inspected |
---|---|---|---|
Leak calibrator (LC Series) |
22,000 | LC Series | – Measurement of the length of LC – Volume comparison – Performance check – Leak check – Overall diagnosis |
27,000 | QLC/LC-88 Series | ||
– Analog pressure gauge (Pressure switch, etc.) * Limited to gauges with serial numbers shown on them. |
21,500 | Basic Inspection | – Pressure accuracy check |
* For information on the products not listed above, contact Cosmo.
Product Name/Specifications | Price(JPY) | Item to be Inspected/Option | |
---|---|---|---|
Within Cosmo’s normal business hours |
Outside Cosmo’s normal business hours |
||
Standard pressure range (LS/LU Series) |
26,000 | 31,000 | – DPS accuracy check – PS accuracy check / Analog pressure gauge accuracy check – No-leak Check – Judgement operation – Insulation resistance check – Overall diagnosis |
+9,500 | – Multi-range inspection (P2/PV) *1 | ||
+6,500 | – Discharge flow check | ||
High pressure range*2 (LS/LU Series) |
19,500 | 24,500 | – DPS accuracy check – DPS leak check – Insulation resistance check – Overall diagnosis |
Micro volume model (LUA/SS Series) |
35,000 | 40,000 | – DPS accuracy check – PS accuracy check / Analog pressure gauge accuracy check – No-leak Check – Judgment operation – Insulation resistance check – Overall diagnosis |
Micro volume detection model (LZ/ZL Series) |
|||
Volume detection model (LSW/LUW/WL Series) |
|||
Air volume tester (AV Series) |
43,000 | 48,000 | – DPS accuracy check – PS accuracy check / Analog pressure gauge accuracy check – No-leak Check – Judgment operation – Insulation resistance check – Overall diagnosis |
Gauge pressure decay model*5 (LSG, GX1 Series) |
31,000 | 35,000 | – PS accuracy check – No-leak Check – Insulation resistance check – Overall diagnosis |
Leak flow sensor unit (AF-2206 Series) |
20,000 | 25,000 | – DPS accuracy check – Flow check – No-leak Check – Judgment operation – Overall diagnosis |
Product Name/Specifications | Price(JPY) | Item to be Inspected/Option | ||
---|---|---|---|---|
Within Cosmo’s normal business hours |
Outside Cosmo’s normal business hours |
|||
Air Flow Tester (AF Series) |
43,000 | 51,000 | – Flow accuracy check – PS accuracy check/ Analog pressure gauge accuracy check – No-leak Check – Judgment operation – Insulation resistance check – Overall diagnosis |
|
+6,500 | -Atmospheric pressure sensor accuracy check | |||
Air flow meter*3*4 (DF Series) * These prices apply only to the air flow meters with the Laminar Flow Tubes removed so that the inspection can be easily conducted. |
48,000 | 53,000 | Standard model: Up to 2 ranges | – Flow accuracy check – Pressure accuracy check (Only for models of the automatic line pressure compensation) – Judgment operation – Insulation resistance check – Overall diagnosis |
64,500 | 69,500 | Standard model: Up to 3 ranges | ||
81,000 | 86,000 | Standard model: Up to 4 ranges | ||
97,500 | 102,500 | Standard model: Up to 5 ranges | ||
114,000 | 119,000 | Standard model: Up to 6 ranges | ||
130,500 | 135,500 | Standard model: Up to 7 ranges | ||
147,000 | 152,000 | Standard model: Up to 8 ranges | ||
54,500 | 59,500 | Automatic line pressure compensation model: Up to 2 ranges | ||
71,000 | 76,000 | Automatic line pressure compensation model: Up to 3 ranges | ||
87,500 | 92,500 | Automatic line pressure compensation model: Up to 4 ranges | ||
104,000 | 109,000 | Automatic line pressure compensation model: Up to 5 ranges | ||
120,500 | 125,500 | Automatic line pressure compensation model: Up to 6 ranges | ||
137,000 | 142,000 | Automatic line pressure compensation model: Up to 7 ranges | ||
153,500 | 158,500 | Automatic line pressure compensation model: Up to 8 ranges | ||
+6,500 | – Atmospheric pressure sensor accuracy check | |||
+6,500 | – Line pressure calibration (per range) | |||
Deviation flow meter (FD Series) |
26,000 | 31,000 | – DPS accuracy check – PS accuracy check/ Analog pressure gauge accuracy check – No-leak Check – Judgment operation – Insulation resistance check – Overall diagnosis |
|
Flow gauge*3 – Mass flow gauge (The same prices apply to the inspection of a Mass Flow Sensor unit) * MF-140 (On-site inspection NOT available) – Laminar flow gauge – Venturi flow gauge |
41,500 | 46,500 | – Flow accuracy check – Judgment operation – Insulation resistance check (Not applied to DP Gauges.) – Overall diagnosis |
|
Deviation flow meter*5 (DF-720) |
||||
Digital conditioner*5 (DC-720 flow meter model) |
||||
+6,500 | – Line pressure inspection |
Product Name/Specifications | Price(JPY) | Item to be Inspected/Option | |
---|---|---|---|
Within Cosmo’s normal business hours | Outside Cosmo’s normal business hours | ||
DP Gauge*5 (DP Series) |
24,500 | 29,500 | – Accuracy check – Insulation resistance check (Not applied to DP Gauges.) – Overall diagnosis |
Digital manometer*3*5 (DM Series) * Inspection specification: ±0.1 % of F.S .±1 digit (On-site inspection NOT available) |
|||
+16,500 | – Pressure/Vacuum range | ||
Digital conditioner /Multi controller *5 (DC-720/MC-720 pressure gauge model) |
26,500 | 31,500 | – Accuracy check – Insulation resistance check – Overall diagnosis |
+16,500 | – Pressure/Vacuum range |
Product Name/Specifications | Price(JPY) | Item to be Inspected/Option | |
---|---|---|---|
Within Cosmo’s normal business hours | Outside Cosmo’s normal business hours | ||
Setting manometer (SM Series) |
46,500 | 51,500 | – Accuracy check – Insulation resistance check – Overall diagnosis – Control check (Adjustment) |
Pressure controller (PC Series) |
|||
Pressure/Flow Controller (PR Series) |
|||
+16,500 | – Pressure/Vacuum range |
Product Name/Specifications | Price(JPY) | Item to be Inspected/Option | |
---|---|---|---|
Within Cosmo’s normal business hours | Outside Cosmo’s normal business hours | ||
Analog pressure gauge (Pressure switch, etc.) * Limited to gauges with serial numbers shown on them. |
20,000 | 25,000 | – Pressure accuracy check |
I/O check * RS-232C I/O check is excluded. |
+6,500 | – External I/O check |
* For information on the products not listed above, contact Cosmo.
Product Name/Specifications | Price(JPY) | Item to be Inspected/Option | |
---|---|---|---|
Within Cosmo’s normal business hours | Outside Cosmo’s normal business hours | ||
Air leak tester (We inspect according to Cosmo’s inspection specifications.) * We do not conduct span adjustment as a rule. |
30,000 | 35,000 | – DPS accuracy check – PS accuracy check / Analog pressure gauge accuracy check – No-leak check – Judgment operation – Overall diagnosis |
Pressure gauge (We check the accuracy in the range from 2 kPa to 1 MPa.) * We do not conduct span adjustment as a rule. |
25,000 | 30,000 | – Pressure accuracy check |
< On-site inspection on other manufacturers’ pressure gauges >
We will issue the Inspection Record only for gauges that have their identification numbers (serial numbers) shown on them. When the pressure gauge to be inspected does not have its serial number on it, inform us beforehand. Cosmo will issue an identification number. (The number cannot be issued on-site.)
< Span Adjustment >
We do not conduct span adjustment as a rule.
For span adjustment, contact us beforehand. We will respond on a case-by-case basis.
– We may ask you to submit to us material that clearly shows how the span should be adjusted.
– If the accuracy specification is not clear, we will use our specification to make pass/fail judgment on the accuracy.
Item | Price(JPY) | Details |
---|---|---|
Travel time cost | 8500/hr/person | 1 hour per person (When the time reaches 30 minutes, it is rounded up to 1 hour.) * Basically, our travel time is limited within our normal business hours (8:30 to 17:30). If we need to travel early in the morning or at night, we may require accommodation. You will be charged for the accommodation. |
Transportation cost | Actual cost | Public transportation fees Toll road fee, ferry fee, etc. |
50/km | Company car fuel cost per 1 km 50 yen Mileage from and to the sales office or the head officeCalculation of travel distance [Actual mileage from the sales office or the head office] x 2 (Round trip) x 50 yen * The mileage is calculated using the car navigation system as a rule. (The actual mileage may be checked with the odometer reading.) |
|
Accommodation cost | 10,000/person | 1 night per person |
When a sufficient number of personnel is required to inspect many number of testers, we may procure them from more than one office.
In such cases, the travel, transportation and accommodation expenses will be calculated and charged for the distances between the customer’s site and the each office.
*1: For P2 and PV models, PS (Test Pressure Sensor) is inspected for both the positive and negative pressures. The price for multi-range inspection is additionally charged. *2: For Air Leak Testers of high pressure range, we do not conduct the Analog pressure gauge accuracy check, PS accuracy check and No-leak Check at customers’ facilities. In case those checks are required, we will conduct them only within the pressure available at the facilities of the customers’. The price for the services for the standard pressure range will be charged. *3: Normally we only provide in-house inspection. *4: The on-site test specification for the Flow accuracy check is “±1.5 % of F.S. ±1 digit”. (It is not same as the test specification for in-house inspection.) *5: In on-site inspection, up to 1 MPa can be inspected. (We will NOT provide on-site inspection for the testers using the absolute pressure scale.) |