Contact/FAQ ダウンロード


Catalog
Download

Leak Master LM-1C / LM-1AH for high pressure

LM-1C/LM-1AH

The leak master LM-1C is ideal for everyday inspections of air leak testers. LM-1AH is for high pressure up to 4.9 MPa.

The LM-1C Series is used as an ideal determination device, so it can be manufactured with your desired leak volume.
Please specify test pressure and leak volume in the range below when ordering.

Edge & Function



Features

* Three models are available:
LM-1C: Customized to the specified pressure and flow, LM-1C-J1 series: Standard model with predetermined flow, LM-1AH for high pressure from 1 MPa to 4.9 Mpa.

● Customized to the specified pressure and flow.

● Accuracy (Difference from the required flow): Within ±5%
For 2 mL/min or less: Within ±10 to 20%.
* High pressure LM: For 0.1 to 0.7 mL/min: Within ±20%, For 0.8 to 50 mL/min: Within ±10%

● Enables to easily and reliably check the sensitivity of Air Leak Testers.

● Maintains the same flow for a long period of time.

● Can also be used for the Secondary Pressure method.

● Can be connected to the CAL port of Air Leak Testers.

● Can be connected to the piping between the work and the tester by using the dedicated adapter.

● By replacing the Leak Master with the dedicated plug, the tester can easily return to the normal test state (no leak state).

● Traceability certificate is available upon request.

Example of use with our Air Leak Tester (High pressure LM-1AH excluded)

Spec



LM-1C Series Specifications

The LM-1C Series is used as an ideal determination device, so it can be manufactured with your desired leak volume.Please specify test pressure and leak volume in the range below when ordering.

Test Pressure Leak volume
Positive pressure 1 ~ 9.9 kPa 0.1 ~ 20 mL/min
10 ~ 99 kPa 0.1 ~300mL/min
100 ~ 999 kPa(※1) 0.1 ~500mL/min
Vacuum pressure -1 ~ -9.9 kPa 0.1 ~ 20 mL/min
-10 ~ -49 kPa 0.1 ~ 100 mL/min
-50 ~ -89 kPa 0.1 ~ 200 mL/min

(※1)Test pressure 1MPa or above is supported with LM-1 AH special order.
Manufactured with requested leak volume in the below accuracy.
・For flow rate 2 mL/min or above, manufactured within ±5% accuracy
・For flow rate 0.8 mL/min or above, manufactured within ±10% accuracy
・For flow rate less than 0.8 mL/min, manufactured at ±20% accuracy
Configuration: LM-1C (with filter joint/clear cover)
Accessories (adapter/plug/filter element/O-ring)

LM-1C-J1 Series Specifications

LM-1C-J1 Series are standardized Leak Masters as shown on the table below.
A data sheet showing actually measured or calculated flows at the test pressure points in the table below will be enclosed.
This series are an ideal standard for the calibration of the air leak tester sensitivity.

Cells in gray are actually measured flow.
□ Cells in white are calculated flow.

Test Pressure LM-1C-J1-1 LM-1C-J1-2 LM-1C-J1-5 LM-1C-J1-10 LM-1C-J1-20 LM-1C-J1-50 LM-1C-J1-100 LM-1C-J1-200
(kPa) (mL/min) (mL/min) (mL/min) (mL/min) (mL/min) (mL/min) (mL/min) (mL/min)
10 0.08 0.16 0.39 0.78 1.6 4.66 10.33 23
20 0.16 0.32 0.78 1.56 3.19 9.32 20.7 45.9
30 0.25 0.5 1.24 2.48 5.03 14.46 31 65.3
40 0.34 0.68 1.7 3.39 6.87 19.6 41.4 84.7
50 0.43 0.87 2.16 4.31 8.71 24.7 51.8 105.8
60 0.54 1.09 2.7 5.4 10.84 29.8 61.7 126.8
70 0.65 1.31 3.25 6.49 12.96 34.9 71.6 145.3
80 0.77 1.52 3.79 7.57 15.09 40 81.2 163.8
90 0.88 1.74 4.34 8.66 17.21 45.1 90.8 182
100* 0.99 1.96 4.88 9.75 19.34 50.2 100.4 200.1
150 1.74 3.31 8.18 16.42 31.7 61.1 147.1
200 2.49 4.65 11.47 23.1 44 102 193.7
250 3.49 6.54 15.52 31 58 128.6
300 4.5 8.44 19.57 39 71.9 155.3
350 5.5 10.33 23.6 46.9 85.9
400 6.5 12.22 27.7 54.9 99.9
450 7.75 14.45 32.2 63.9 115.2
500 9.01 16.68 36.7 72.9 130.5
550 10.26 18.9 41.2 81.9 145.8
600 11.51 21.1 45.7 90.9 161.2

(The flow rates in the table above are some examples)

*LM-1C-J1 Series are manufactured within ±5% accuracy of each standard flow at test pressure of 100 kPa except for 1 mL/min.For flow rate 1 mL/min, manufactured within ±10% accuracy.
● Configuration:LM-1C-J1 (with filter joint/clear cover), Accessories (adapter/plug/filter element/O-ring)
*Purchase the adapter and plug when connecting Leak Master between tested part and WORK port.

LM-1AH Specifications

Use the LM-1AH for high pressure.
The pressure is available from 1 to 4.9 MPa. Check the specified flow at high pressure.

■ LM-1AH High Pressure Production Range
Test Pressure:1 to 4.9 MPa
Flow:0.1 to 50 mL/min

■ LM-1AH / Accuracy (Difference from the required flow) and minimum unit

Required flow mL/min Accuracy Minimum unit mL/min
0.1 to 0.7 Within ±20% 0.1
0.8 to 19.9 Within ±10% 0.1
20 to 50 Within ±10% 1

■ Main Body:LM-1C / LM-1AH (With a filter joint and an acrylic cover)

Converting adapter

Those Converting adapters for Leak Master are available:

Part Number Male Screw Size Female Screw Size Use
7201ALAL R1/8 M10×1.5 Connect LM-1C to the middle of the piping (RC1/8 socket). Included with LM-1C(R1). (*)
7201ALAZ R1/4 M10×1.5 Connect LM-1C to the middle of the piping (RC1/4 socket). Included with LM-1C(R2). (*)
7201ALAX M10×1.5 RC1/4 Connect R1/4 fitting to the CAL port of Air Leak Tester.
7201ALAV M10×1.5 RC1/8 Connect R1/8 fitting to the CAL port of Air Leak Tester.
73010RBV R1/8 RC1/8 Connect LM-1AH to the middle of the piping (RC1/8 socket). Included with LM-1AH(R1).
7201ALDP R1/4 RC1/4 Connect LM-1AH to the middle of the piping (RC1/4 socket). Included with LM-1AH(R2).

(*) Not included with LM-1C-J1.

Classification



lm-1c-classification



Appearance